Calibration and Validation Services

CALIBRATION SERVICE

Temperature - Humidity - Voltage - Resistance

We offer a fully compliant calibration service for laboratory and pharmaceutical equipment. Our services include:

  • Single point Temperature Calibration
  • Single point Temperature and Humidity Calibration
  • PID Controller Calibration
  • RTD Calibration
  • Chiller Temperature Calibration
  • Air Flow Calibration
     

All Traceable instruments are Calibrated to UKAS and NIST industry standards.

Temperature Calibration

 We offer single and multi-point temperature calibration testing to UKAS and NIST industry standards for cold chain and ICH conditions. We specialize in Freezers, Fridges, Ovens, Incubators, Autoclaves, Environmental Chambers and Laboratory equipment.

-80°C, -70°C, -40°C, -20°C, 0°C, 5°C, 50°C

Temperature & Humidity
Calibration

Temperature and relative humidity calibration is available for single or multi point verification.  We specialize in Freezers, Fridges, Environmental Chambers and Laboratory Equipment.

5°C, 25°C/60%RH, 30°C/65%RH, 30°C/75%RH

40°C/25%RH, 40°C/75%RH, BESPOKE

Validation & Verification

ICH Nominal Guideline Testing

Our fully 21 CFR Part 11 compliant Data Logging system, combined with Rotonic HC2A Temperature / Humidity probes, allows us to accurately monitor and record your equipment. We provide all protocols specific to your requirements and provide Charted, Raw Data and a full process audit trail. All documentation is completed to CGMP standards and prechecked prior to customer submission.



 5°C, 25°C/60%RH, 30°C/65%RH, 30°C/75%RH 40°C/25%RH, 40°C/75%RH, BESPOKE

We validate using a 48 channel Eurotherm 6000 series data logger. Recording real-time data using 21 CFR part 11 software.

We use Rotronic HC2A-S Temperature and Humidity probes. their reliability and test specification allows us to accurately map and document equipment performance 

 

We specialize in testing ICH stability conditions in line with FDA , MHRA, and HPRA regulatory standards

ICH Nominal Guidelines

Cold Chain

Bespoke Conditions

ICH

We test stability equipment to ICH nominal Guidelines, all environmental chambers, incubators, ovens are tested to ensure performance with in the alarm criteria for each condition.

Cold Chain

Cold chain solutions, we test and map all cold chain conditions down as low as -80°C

Bespoke

Our Data loggers can be calibrated to perform custom conditions for bespoke requirements. 

Validation Tests we Offer:

Pre-Calibration Test 
Minimum of 24 Hour Unloaded Validation Test
1 Minute Unloaded Door Open Recovery Test
Minimum of 24 Hour Loaded Validation Test
1 Minute Loaded Door Open Recovery Test
Optional:
Post Calibration Test
Power failure recovery Test

All Validation protocols are controlled and generated specifically to the customers' requirements. Each protocol will include a Validation Chart, Raw Data sheet and a full audit trail of the performance test completed. All documentation is completed to GDP and cGMP standards and will have a pre-Quality check prior to being received by the customer.

Service Level Agreements

PMI - VALIDATION - EMERGENCY SERVICE

Our Service Level agreements allow our customers to schedule in advance annual or biannual services, we offer services packages catered to your exacting standards and requirements. There are many advantages to having the knowledge that your service is prioritized and scheduled. The main benefit is we offer discounted pricing to all contracted customers for our services. Annual contracts are invoiced at time of service so there is no impact on your yearly CAPEX obligations.